Truck Scale Load Cell
Model: LCC-HSD
Hermetically Sealed Double Ended Shear Beam Load Cell

NTEP Certified (legal for trade) models also available

DESCRIPTION:

The Model HSD is a hermetically sealed and center-supported shear beam. Ideal for the harsh environments of truck scales, the heat-treated high alloy tool steel construction provides optimum protection under impact loading and adverse conditions. The parallel link loading design provides free horizontal movement to eliminate the error induced by side forces or deflection of the structure. When installed with Load Cell Centrals Duramount 2 mounting hardware, check rods and other centering devices are not required.

Specifications:

Standard Capacities: 50K, 65K, 100K lb.
Output: 3 mV/V ± 0.25%
Combined Error: 0.025%
Non-Repeatability: 0.02%
Creep (20 minutes): 0.025%
Zero Return: 0.025%
Thermal Sensitivity Shift: 0.0012%/°C
Thermal Zero Shift: 0.004%/°C
Comp. Temp. Range: -10°C to +40°C
Operating Temp. Range: -20°C to +60°C

Zero Balance: ±1%
Input Resistance: 770 ± 10 ohm
Output Resistance: 700 ± 3 ohm
Standard Cable: 50 ft.
Insulation Resistance: >5000 M-ohm
Full Scale Deflection: < 0.4 mm
Recommended Excitation: 10V
Maximum Excitation: 15V
Safe Overload: 150%
Ultimate Overload: 200%

 

 

Load Cell main page