MEDIUM CAPACITY
SINGLE POINT LOAD CELL
Model: LCC-GCB1

  • Direct Interchange for the 1040 and 652 load cells

Capacities: (kg) 5, 7, 10, 15, 20, 30, 50, 100SE, 100, 150, 250, 300, 500, 635

Description:

Load Cell Central's LCC-GCB1 low cost, low profile off center* load cell is designed for weighing platforms, hanging scales, bench scales, and many other low capacity beam applications. The LCC-GCB1 is constructed of anodized aluminum and is environmentally sealed against moisture and humidity.
* The "off-center" or moment compensation feature allows for support by a single load cell at the center of the platform. Up to the specified platform size limit (which for this model is 16" x 16"), the cell will weigh within stated accuracy specifications independent of where the load is positioned on the platform.

Load Cell Dimensions:

Capacity (kg)
L
L1
L2
W
W1
H
H1
T
5, 7, 10, 15, 20, 30, 50, 100SE (mm)
150.0
19.0
100.0
30.0
24.0
39.5
19.0
M6x1.0
(inch)
5.91
0.75
3.94
1.18
0.94
1.56
0.75
100, 150, 250, 300, 500, 635 (mm)
174.0
19.0
122.0
60.0
30.0
65.0
-
M8x1.25
(inch)
6.85
0.75
4.80
2.36
1.18
2.56
-

 

Load Cell Specifications:

Output: 2mV/V ±10%
Maximum Recommended Platform Size: 5-100SE kg: 16"x16", 100 - 635kg: 16"x24"

Combined Error: 0.025%
Non-Repeatability: 0.02%
Creep (20 minutes) : 0.03%
Zero Return (20 minutes): 0.03%
Thermal Sensitivity Shift: 0.015%/°C
Thermal Zero Shift: 0.0026%/°C
Compensated Temperature Range: -10° to 40°C
Operating Temperature Range: -20° to 60°C
Zero Balance: ±3% R.O.
Input Resistance: 410 ±10 Ohm
Output Resistance: 350 ±3 Ohm
Recommended Excitation: 10 Volts
Insulation Resistance (50 VDC): >5000 M/ohm
Safe Overload: 150%
Ultimate Overload: 200%

 

Load Cell main page