Model OM-25 Load Cell Signal Conditioner 0-10V Output

Load Cell Signal Conditioner 0-10V Output

The unit is a DIN Rail mount, self-contained DC powered module designed for load cell, strain gage, or single ended use. It contains a precision instrumentation amplifier, filtered output and a built-in 10VDC excitation supply capable of driving a 350 ohm bridge. The 0 to 30mV input range makes it compatible with most strain gauge based load cell or pressure transducer outputs. It provides an output of 0 to 10VDC. Connections are made via easily accessible screw clamp terminal blocks. Zero and Span adjustment potentiometers are located externally as well for easy access.

Features:

  • Low Cost
  • Din Rail Mount
  • Load Cell or Single Ended Application
  • 0-30mVDC Input
  • 0-10VDC Output

Reviews

Online ordering coming soon

There are no reviews yet for this product. Write a Review

Share this page

add to cartProduct Pricing

Part No.DescriptionPriceQty.
OM-25Load Cell Amplifier 0-10V Output, 24VDC Operational, Powers a Single 350Ω Load Cell$455.00

add to cart

 

OM-25 internal diagramOM-25 diagram

OM-19 specifications

Brochures

There are no reviews yet for this product. Write a Review

Product Bulletins