5 Key Benefits Of Through-Hole Load Cells
September 10, 2026
Quick Summary
A through-hole load cell allows a bolt, rod, or shaft to pass through its center while measuring force applied to the sensor body. Compression-style designs are useful for bolt load monitoring, clamping force measurement, and suitable press applications. Their compact form and range of bore sizes offer installation options, but accurate readings depend on properly designed loading surfaces and alignment.

A through-hole load cell can solve a practical installation problem: measuring force where a bolt, rod, or shaft needs to pass through the sensor. Its ring-shaped body fits around the component, allowing force measurement within the assembly.
This arrangement can be useful in compact machinery, test fixtures, and retrofit projects. At Load Cell Central, we can help you review the available space, expected forces, and mounting requirements before selecting a model.
What Is a Through-Hole Load Cell?
A through-hole load cell has a central opening surrounded by a force-sensing body. These sensors are also called donut load cells or load washers.
In the compression-style designs discussed here, force is applied between opposing loading faces. The bolt or shaft passes through the opening, while the surrounding sensor body carries the compressive load.
Simply passing a component through the hole does not measure its force. The assembly must transfer the force being measured through the sensor’s designated loading surfaces.
Common applications include bolt preload measurement, clamping force monitoring, and press force measurement where the tooling and support arrangement suit the sensor.
How a Through-Hole Load Cell Works
Bonded strain gauges detect the small deformation of the sensing element under load. Connected in an electrical bridge circuit, the gauges produce a signal that compatible electronics convert into a force reading.
For example, a load washer positioned beneath a bolt head or nut can measure the compressive reaction associated with tension in the bolt. The sensor remains in compression even though the bolt is in tension.
This does not mean every through-hole model can measure direct tension. The sensor’s rated loading mode and the design of the complete assembly determine how it can be used.
The bore also does not automatically center the force. Flat, parallel loading surfaces and properly aligned hardware are important for distributing the load as intended.
1. Compact Installation Around a Bolt or Shaft
The central opening allows a sensor to fit around hardware that would obstruct a solid-center design. This can make force measurement practical where access and surrounding space are limited.
Check the complete installed dimensions, including the sensor, loading plates or washers, and cable exit. Adding a load cell still requires space and may change the assembly’s height.
2. Direct Measurement of Compressive Reaction Force
A load washer provides a way to measure force within a clamped connection. When properly installed, it measures the compressive force transmitted through its loading faces.
This can help engineers evaluate bolt preload or compare clamping forces during testing. The result applies to the force passing through the sensor; any alternative load path must be considered when interpreting the reading.
3. Useful Across Several Force Measurement Applications
The same general form can serve bolt testing, clamping fixtures, press setups, and certain rod or cable anchoring arrangements.
For example, tension in a rod can be measured indirectly when an end fitting transfers that force into compression against the sensor. Each application needs a suitable load path, rather than relying on the center hole alone.
4. Stainless Steel Construction Options
Load Cell Central’s through-hole range includes stainless steel designs for industrial force measurement. Our VCD model, for example, uses heat-treated stainless steel and a sealed strain-gauge sensing element.
Environmental suitability remains model-specific. Review temperature limits, sealing, chemical exposure, and cable protection before selecting a sensor for outdoor, wet, or demanding production conditions.
For repeated or dynamic loading, confirm that the selected model and mounting arrangement suit the expected load cycles and peak forces. Stainless steel construction alone does not establish fatigue life or overload resistance.
5. Size and Capacity Options for Existing Assemblies
Different bore sizes, outside diameters, and capacities provide options for fitting a sensor around existing hardware. Our through-hole load cells include several model sizes to help match the available space and load range.
A retrofit still requires a mechanical review. Sensor thickness, available fastener engagement, loading surfaces, and the stiffness of the connection can affect whether the installation is practical.
How to Install and Verify This Sensor Type
Start with the selected model’s drawing and installation requirements. The following checks help establish a suitable setup:
- Match capacity to the complete load case: Include initial preload, the expected operating range, and any dynamic or impact forces. Do not use the overload rating as normal operating capacity.
- Check all installation dimensions: Confirm the bore clearance, outside diameter, sensor height, and space for cables and loading hardware.
- Provide suitable loading surfaces: Use the specified contact areas and flat, parallel surfaces. Loading plates or washers must suit the sensor’s requirements.
- Maintain alignment: Avoid unintended contact between the bolt or shaft and the bore. Check that the assembly does not introduce side forces or uneven loading.
- Follow the assembly instructions: Secure the hardware as specified without creating an unintended load path around the sensor.
- Protect the signal cable: Prevent cable strain and route it away from moving parts, sharp edges, and electrical interference.
- Verify the installed system: Check readings against suitable known loads across representative operating points before relying on the measurements.
If the sensor is preloaded during assembly, record that condition. Zeroing the display afterward changes the displayed reference; it does not remove the physical load already carried by the sensor.
If a standard model does not meet your dimensions or performance requirements, we can help review options within our broader range of load cells and force sensors, including custom solutions where appropriate.
Choosing the Right Sensor for Your Installation
A through-hole design is useful when the sensor needs to fit around a component and the assembly can transfer force through its loading faces. The best choice depends on more than bore size: capacity, accuracy, installed height, loading surfaces, electronics, and environmental conditions all matter.
Contact Load Cell Central with your bolt or shaft diameter, expected preload and operating forces, available space, and assembly drawing. We can help you compare suitable sensors and identify mounting details that need attention.
FAQs
What is a through-hole load cell used for?
Compression-style through-hole cells are used for bolt preload measurement, clamping force monitoring, and suitable press or test fixtures. They can also measure tension indirectly when the assembly converts that force into compression on the sensor.
How does alignment affect a through-hole load cell’s accuracy?
Uneven or off-center loading can affect readings. The center hole does not automatically align the force, so use the specified loading surfaces, maintain the required clearances, and follow the model’s installation guidance.
Is a through-hole load cell harder to install than other sensor types?
That depends on the assembly. The central opening can simplify placement around a bolt or shaft, but the installation still needs suitable loading faces, adequate space, and a controlled load path.
What should I check before relying on its readings?
Confirm capacity, preload, bore clearance, loading surfaces, wiring, and electronics settings. Then verify the complete installed system against suitable known loads over the intended measuring range.
Can a through-hole load cell handle demanding industrial environments?
Some models are suitable for demanding conditions, but check the specific ratings. Material, sealing, temperature limits, cable protection, and suitability for repeated or dynamic loading all affect the choice.